Milliwatt Configuration
Create a document (with milliwatt
for id
) in the system_config
database.
Base Parameters
echo
duration
This sets the duration of the echo action. The value is in milliseconds. Sample Code:
duration: 5000
caller_id
This sets the caller ids of the echo action. It means that any call made from theses numbers (or users) will be redirected to Milliwatt echo action. Sample Code:
caller_id: [4155555555, username]
number
This sets the number of the echo action. It means that any call made to these numbers will be redirected to Milliwatt echo action. Sample Code:
number: [123456789,1011121314]
Sample Code
echo: {duration : 5000
,caller_id: [
4155555555,username
],
number: [123456789]}
tone
frequencies
This sets the frequencies used for the tone action. Sample Code
frequencies: [2600, 2300]
duration
This sets the duration of the tone action. The value is in milliseconds. Sample Code
duration: 5000
caller_id
This sets the caller ids of the tone action. It means that any call made from theses numbers (or users) will be redirected to Milliwatt tone action. Sample Code
caller_id: [4155555555, username]
number
This sets the number of the tone action. It means that any call made to these numbers will be redirected to Milliwatt tine action. Sample Code
number: [
123456789,1011121314]
Sample Code
tone: {
frequencies: [2600]
,duration: 5000
,caller_id: [4155555555
,username
]
,number: [123456789]
}
Sample Code:
{_id: milliwatt,default: {echo: {duration
: 5000
,caller_id: [username_echo ],
number: [5555555551]
}
,tone: {frequencies:[2600]
,duration: 2000
,caller_id: [username_tone]
,number: [5555555552]
}
}
}